Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Eur Phys J Plus ; 138(5): 391, 2023.
Article in English | MEDLINE | ID: covidwho-2323673

ABSTRACT

Medical imaging has been intensively employed in screening, diagnosis and monitoring during the COVID-19 pandemic. With the improvement of RT-PCR and rapid inspection technologies, the diagnostic references have shifted. Current recommendations tend to limit the application of medical imaging in the acute setting. Nevertheless, efficient and complementary values of medical imaging have been recognized at the beginning of the pandemic when facing unknown infectious diseases and a lack of sufficient diagnostic tools. Optimizing medical imaging for pandemics may still have encouraging implications for future public health, especially for long-lasting post-COVID-19 syndrome theranostics. A critical concern for the application of medical imaging is the increased radiation burden, particularly when medical imaging is used for screening and rapid containment purposes. Emerging artificial intelligence (AI) technology provides the opportunity to reduce the radiation burden while maintaining diagnostic quality. This review summarizes the current AI research on dose reduction for medical imaging, and the retrospective identification of their potential in COVID-19 may still have positive implications for future public health.

2.
Med Image Anal ; 86: 102787, 2023 05.
Article in English | MEDLINE | ID: covidwho-2308518

ABSTRACT

X-ray computed tomography (CT) and positron emission tomography (PET) are two of the most commonly used medical imaging technologies for the evaluation of many diseases. Full-dose imaging for CT and PET ensures the image quality but usually raises concerns about the potential health risks of radiation exposure. The contradiction between reducing the radiation exposure and remaining diagnostic performance can be addressed effectively by reconstructing the low-dose CT (L-CT) and low-dose PET (L-PET) images to the same high-quality ones as full-dose (F-CT and F-PET). In this paper, we propose an Attention-encoding Integrated Generative Adversarial Network (AIGAN) to achieve efficient and universal full-dose reconstruction for L-CT and L-PET images. AIGAN consists of three modules: the cascade generator, the dual-scale discriminator and the multi-scale spatial fusion module (MSFM). A sequence of consecutive L-CT (L-PET) slices is first fed into the cascade generator that integrates with a generation-encoding-generation pipeline. The generator plays the zero-sum game with the dual-scale discriminator for two stages: the coarse and fine stages. In both stages, the generator generates the estimated F-CT (F-PET) images as like the original F-CT (F-PET) images as possible. After the fine stage, the estimated fine full-dose images are then fed into the MSFM, which fully explores the inter- and intra-slice structural information, to output the final generated full-dose images. Experimental results show that the proposed AIGAN achieves the state-of-the-art performances on commonly used metrics and satisfies the reconstruction needs for clinical standards.


Subject(s)
Image Processing, Computer-Assisted , Positron-Emission Tomography , Humans , Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Attention
3.
Eur J Nucl Med Mol Imaging ; 48(8): 2500-2524, 2021 07.
Article in English | MEDLINE | ID: covidwho-1208672

ABSTRACT

Medical imaging methods are assuming a greater role in the workup of patients with COVID-19, mainly in relation to the primary manifestation of pulmonary disease and the tissue distribution of the angiotensin-converting-enzyme 2 (ACE 2) receptor. However, the field is so new that no consensus view has emerged guiding clinical decisions to employ imaging procedures such as radiography, computer tomography (CT), positron emission tomography (PET), and magnetic resonance imaging, and in what measure the risk of exposure of staff to possible infection could be justified by the knowledge gained. The insensitivity of current RT-PCR methods for positive diagnosis is part of the rationale for resorting to imaging procedures. While CT is more sensitive than genetic testing in hospitalized patients, positive findings of ground glass opacities depend on the disease stage. There is sparse reporting on PET/CT with [18F]-FDG in COVID-19, but available results are congruent with the earlier literature on viral pneumonias. There is a high incidence of cerebral findings in COVID-19, and likewise evidence of gastrointestinal involvement. Artificial intelligence, notably machine learning is emerging as an effective method for diagnostic image analysis, with performance in the discriminative diagnosis of diagnosis of COVID-19 pneumonia comparable to that of human practitioners.


Subject(s)
COVID-19 , Pneumonia, Viral , Artificial Intelligence , Humans , Positron Emission Tomography Computed Tomography , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL